Karnot iHEAT R290 100kW

Commercial Monobloc Air Source Heat Pump — 380–420V 3-Phase

A+++COP up to 4.9175°C Output−25°C OperationR290 · GWP 3380–420V 3-PhaseCommercial Grade

100kW Commercial Monobloc Air Source Heat Pump

Natural Refrigerant R290 · A+++ Rated · 3-Phase

The iHEAT 100kW is Karnot’s flagship large commercial unit — designed for district heating, large hotels, hospitals, industrial facilities, and anchor commercial buildings. Twin HITACHI inverter scroll compressors with dual DC fans deliver 100kW heating, 87.5kW cooling, and 75°C output. Multiple units cascade for loads exceeding 200kW, with G2½" water connections for high-flow commercial hydronic systems.

A+++ Energy RatingCE CertifiedSG Ready
Karnot iHEAT R290 100kW

Integrated iSAVE™ AI Platform

Blockchain-Verified Carbon Monitoring & Grid Optimisation

Carbon Credit Monetisation

Blockchain-verified emissions data enables automatic generation and sale of carbon credits, creating recurring revenue from commercial heat pump operations.

Virtual Power Plant Ready

Participate in demand response programmes, earning incentives by shifting commercial thermal loads during peak pricing periods.

Real-Time Performance Optimisation

Cloud-based models continuously tune system parameters, maximising COP and reducing operational costs by 15–25%.

Predictive Maintenance Analytics

Machine learning detects anomalies and predicts failures weeks in advance, reducing downtime and maintenance costs by up to 40%.

Solar PV Self-Consumption

Intelligent thermal storage optimisation maximises on-site solar use, reducing grid dependency and accelerating commercial ROI.

Tamper-Proof Data Integrity

Integrated UPS and cryptographic verification ensure auditable emissions tracking for ESG reporting and carbon credit certification.

Commercial Revenue Enhancement: iSAVE transforms heat pumps into revenue-generating assets through carbon credits, demand response payments, and reduced energy procurement. Typical installations see 8–15% additional annual returns beyond energy savings alone.

Key Features at a Glance

Wide Operating Range

Reliable performance from −25°C to 45°C ambient — full UK year-round commercial operation with no auxiliary heating required.

75°C Hot Water

High-temperature output meets commercial sanitation and L8 Legionella control requirements without auxiliary electric heating.

CHICO Touchscreen

Intuitive 4.3” CHICO touchscreen controller for on-site management by facilities teams and service engineers.

HITACHI Inverter Scroll (×2)

High-efficiency inverter technology delivers precise temperature control, wide part-load range, and commercial-grade reliability.

78 dBA (est.) Sound Level

Design for commercial plant rooms with appropriate acoustic separation from occupied areas per planning conditions.

Future-Proof R290

R290 (GWP 3) is PFAS-free and meets EU F-gas GWP 150 limits from 2027 — no refrigerant retrofit required.

Commercial & Industrial Applications

The iHEAT 100kW delivers commercial-grade heating, cooling, and hot water from a single outdoor unit — replacing gas boilers with zero-combustion clean energy.

Commercial Buildings

Offices, hotels, schools, and healthcare facilities benefit from the 100kW’s high capacity, 75°C output, and A+++ efficiency.

Hydronic Efficiency

Water is 3,500× more efficient than air for thermal transfer — enabling zoned distribution and lower carbon footprint at commercial scale.

ESG & Sustainability

R290 + iSAVE blockchain monitoring provides auditable carbon data for ESG reporting, BREEAM assessments, and EPC improvements.

Commercial Benefits & ROI

The 100kW delivers compelling commercial economics — replacing gas boilers while improving energy performance, reducing carbon, and generating new revenue streams.

50–70% Energy Cost Reduction

Replacing gas heating with the 100kW typically reduces heating energy costs by 50–70% at current gas/electricity price ratios.

Cascade & Modular

Multiple units cascade for larger loads with lead-lag sequencing for efficiency and built-in redundancy.

Full Cooling Capability

87.5kW cooling via iZONE fan coils provides summer comfort — complete all-season climate from one outdoor unit.

Legionella-Safe Hot Water

75°C output meets BS EN 806 and L8 requirements for commercial hot water — no supplementary electric heating needed.

iSAVE Carbon Income

Blockchain-verified carbon credits generate ongoing revenue independent of government grant schemes, improving project IRR.

Low Maintenance

Inverter technology and predictive analytics reduce service intervals and emergency call-out costs vs traditional boiler plant.

Funding & Incentives

MCS-Certifiable

iHEAT range is MCS-certifiable for eligible non-domestic applications. Contact Karnot for project qualification.

iSAVE Carbon Revenue

Blockchain-verified carbon credits generate ongoing income independent of government scheme timelines.

Commercial enquiries: Contact Karnot for project-specific assessment, heat loss calculations, and system design support.

Performance

Max Heating Output (A7/W35)100.0 kW
Heating COP Range (A7/W35)3.71 – 4.91
Max Cooling Output (A35/W18)87.5 kW
Cooling EER Range (A35/W18)3.70 – 3.71
Ambient Operating Range−25 °C to 45 °C

Technical Specifications

Order ReferenceCGK-300V4-B
Power Supply380–420V / 3Ph / 50Hz
Max Operating Current62.80 A
Recommended Breaker80 A
CompressorHITACHI Inverter Scroll (×2)
Control SystemCHICO 4.3” Touchscreen
Refrigerant / ChargeR290 / 9.4 kg (GWP 3)
Sound Pressure Level78 dBA (est.) @ 1m
Water ConnectionG2½" BSP
Fan ConfigurationDual DC fans · 32,000 m³/hr total

Dimensions & Weight

Unit Dimensions (L×D×H)2200 × 1100 × 1966 mm
Net Weight665 kg

Premium Components

FUJIKOKI® Electronic Expansion Valve

Precise refrigerant flow control across all operating conditions enhances COP at part-load and maximises performance during seasonal extremes.

Plate Heat Exchanger

High-efficiency brazed plate heat exchanger ensures optimal thermal transfer between refrigerant and water circuits — compact, durable, and resistant to fouling.

DC Variable-Speed Fan

Variable-speed DC fan adjusts to match the thermal load — reducing power consumption and noise during part-load operation while extending component life.

SENSATA Pressure Sensors

High and low pressure monitoring (0–4.6 MPa and 0–2.0 MPa) provides continuous refrigerant circuit protection and predictive fault detection.

Control & Integration

CHICO 4.3” Touchscreen Controller

Colour touchscreen provides on-site management with real-time status, operating history, and alarm logs for facilities managers and service engineers.

Key Functions:

  • Heating, cooling, and DHW management with independent set-points.
  • Weather compensation and climate curve management.
  • Anti-Legionella, Defrost, and Antifreeze automated safety cycles.
  • Multi-zone circulation pump control.
  • Alarm logging with integrated fault diagnostics.
  • SG Ready input for smart grid demand response optimisation.
Disclaimer: Specifications are subject to change without notice. Confirm all details before placing an order. Commercial installations should be designed and commissioned by a qualified heat pump engineer. Contact Karnot for project-specific guidance.

Frequently Asked Questions

What applications is the Karnot iHEAT 100kW designed for?

The 100kW is designed for large commercial and light industrial applications: large hotels, hospitals, food processing facilities, industrial process heating, and district heating schemes. With 87.5kW simultaneous cooling capacity, it handles year-round thermal loads. Multiple units can be cascaded with modular controls.

Does the CGK-300V4-B have redundancy?

Yes. The CGK-300V4-B uses dual independent HITACHI Inverter Scroll compressor circuits. If one circuit requires maintenance, the other continues operating at reduced capacity — critical for applications where thermal supply continuity is essential.

What is the R290 charge on the 100kW unit?

The CGK-300V4-B holds 9.4kg of R290 across two independent 4.7kg circuits. R290 (propane) has a GWP of 3, is PFAS-free, and is classified as A3 flammable — the unit is designed with safe-charge engineering to meet EN 378 and IEC 60335-2-40 requirements.