Back to iCRYO Range

iCRYO 10

10kW Air-Cycle Ultra-Low Temperature CryoChiller

The Karnot iCRYO 10 utilises revolutionary air-cycle technology for ultra-low temperature applications from -40°C to -110°C. Using only natural air (R729) as the refrigerant, this system delivers zero GWP, zero ODP, and completely oil-free operation for pharmaceutical, semiconductor, and research applications.

Zero GWP Oil-Free R729 (Air) CE Certified
Karnot iCRYO 10 — 10kW air-cycle CryoChiller unit

Key Features at a Glance

Ultra-Low Temperatures

Operates from -40°C to -110°C with stable, reliable performance for the most demanding cryogenic applications.

Natural Air Refrigerant

Uses only R729 (air) as refrigerant — zero GWP, zero ODP, zero TFA. Completely natural and free.

100% Oil-Free

Turbo-compressor design eliminates oil contamination risks and reduces maintenance requirements significantly.

Rapid Auto-Restart

Automatically restores all parameters within 30 seconds after power interruption for continuous operation.

Variable Load Operation

Partial load capability ensures high energy efficiency and flexible response to specific cooling demands.

Snow Trap Protection

Integrated humidity extraction prevents frost buildup, eliminating energy-consuming defrost cycles.

Ideal Applications

The iCRYO 10 is engineered for advanced industrial and research applications requiring stable ultra-low temperatures.

Semiconductor Testing

Precise temperature control for device performance evaluation and dry etching processes requiring extreme cold.

Pharmaceutical Freeze-Drying

Lyophilisation of vaccines, antibiotics, and biologics with stable, contamination-free temperature control.

Chemical Process Control

Precise reaction temperature management for exothermic processes and high-purity chemical synthesis.

Biological Sample Storage

Freeze chambers for long-term preservation of biological materials, tissue samples, and research specimens.

Space Equipment Testing

Simulating extreme space environment conditions for materials testing and component qualification.

Cryotherapy Applications

Medical and sports recovery treatments requiring controlled exposure to ultra-low temperature air.

Performance Characteristics

Cooling Capacity & Power Consumption vs. Temperature

Performance Specifications

Temperature Range-40°C to -110°C
Cooling Capacity @ -40°C5.65 kW
Cooling Capacity @ -70°C4.37 kW
Cooling Capacity @ -110°C2.49 kW
Air Supply to Chamber250 – 600 kg/h

Technical Specifications

RefrigerantR729 (Natural Air)
Compressor TypeKarnot Turbo-Compressor (Water-Cooled)
Rated Motor Power10.5 kW
Power Supply3 PE+N, 400V, 50Hz
Maximum Current63 A
Recommended Breaker80 A
Sound Pressure Level70 dBA @ 1m (Maximum)

Dimensions & Weight

Dimensions (L×W×H)1030 × 1330 × 1790 mm
Net Weight800 kg (± 50 kg)
Cabinet MaterialIndustrial Grade Steel with Powder Coating

Advanced Air-Cycle Technology

Open-Cycle Design

The system operates on the principle of an open-air cycle: air passes through an integrated snow trap, is cooled by the turbo module, and is then delivered to the client's chamber at the specified temperature. This ensures reliable and stable performance even at extremely low temperatures.

Zero Environmental Impact

By using natural air (R729) as the refrigerant, the iCRYO 10 achieves zero Global Warming Potential (GWP), zero Ozone Depletion Potential (ODP), and produces no TFA (trifluoroacetic acid). Air is free, abundant, and requires no specialised handling or disposal.

Oil-Free Turbo-Compressor

The advanced turbo-compressor design operates completely oil-free, eliminating contamination risks critical for pharmaceutical, semiconductor, and food applications. This also dramatically reduces maintenance costs and extends component lifespan.

Snow Catcher System

Humidity Extraction Device (HED)

At ultra-low temperatures, moisture in the air instantly converts to snow. The integrated Snow Catcher — a Humidity Extraction Device — prevents frost buildup on products and equipment, eliminating the need for energy-consuming defrost cycles.

Continuous Operation

Unlike traditional cryogenic systems that require periodic defrosting (causing temperature fluctuations and product quality concerns), the iCRYO 10 operates continuously without interruption, maintaining stable temperatures and ensuring consistent process conditions.

Control & Safety Features

Intelligent Load Management

Partial load operation capability ensures high energy efficiency by matching cooling output to actual demand, reducing unnecessary power consumption during low-demand periods.

Rapid Recovery

In the event of power interruption, the system automatically restarts and restores all operational parameters within 30 seconds, minimising disruption to critical processes and protecting sensitive materials.

Technical Drawing

iCRYO 10 technical dimensional drawing showing front and side elevations
Disclaimer: Specifications are subject to change without notice. Please confirm all details before placing an order. Performance data based on water cooling at 6°C. Actual performance may vary based on installation conditions and cooling water temperature.

Interested in the iCRYO 10?

Contact our specialist team to discuss your ultra-low temperature application