Engineering Unit Converter

Convert flow rates, pressures, energy, temperature, and pipe sizes instantly. Built for HVAC, refrigeration, and plumbing engineers who need quick, accurate imperial-to-metric conversions on site or at the desk.

This free converter handles GPM to litres per second, PSI to Bar, BTU/h to kW, Celsius to Fahrenheit, millimetres to inches, and DN-to-NPS pipe sizing. All conversions are bidirectional and update in real time as you type.

Flow Rate Converter

Common Flow Rate Conversions

FromToMultiply by
1 US GPML/min3.78541
1 US GPML/s0.0630902
1 US GPMm³/h0.227124
1 Imp GPML/min4.54609
1 m³/hL/min16.6667
1 m³/hL/s0.277778

Pressure Converter

Common Pressure Conversions

FromToMultiply by
1 PSIBar0.0689476
1 PSIkPa6.89476
1 BarPSI14.5038
1 BarkPa100
1 atmkPa101.325
1 atmmmHg760
1 atminHg29.9213
1 atmmH₂O10.3323

Energy / Power Converter

Common Energy / Power Conversions

FromToMultiply by
1 kWBTU/h3,412.14
1 kWkcal/h859.845
1 kWHP1.34102
1 TRkW3.51685
1 TRBTU/h12,000
1 HPkW0.7457

Temperature Converter

Temperature Formulas

ConversionFormula
°C to °F°F = °C × 9/5 + 32
°F to °C°C = (°F − 32) × 5/9
°C to KK = °C + 273.15
°F to °R°R = °F + 459.67

Length / Distance Converter

Common Length Conversions

FromToMultiply by
1 inchmm25.4
1 footmm304.8
1 yardm0.9144
1 mfeet3.28084
1 minches39.3701

Pipe Sizing Quick Reference

Look up nominal pipe sizes across DN (metric), NPS (imperial), and actual outside diameter. Type a value to filter.

DN (Metric)NPS (Imperial)Actual OD (mm)Actual OD (inches)
DN151/2"21.30.840"
DN203/4"26.71.050"
DN251"33.41.315"
DN321 1/4"42.21.660"
DN401 1/2"48.31.900"
DN502"60.32.375"
DN652 1/2"73.02.875"
DN803"88.93.500"
DN1004"114.34.500"
DN1255"141.35.563"
DN1506"168.36.625"
DN2008"219.18.625"
DN25010"273.010.750"
DN30012"323.812.750"

Frequently Asked Questions

How do I convert GPM to litres per second?
To convert US gallons per minute (GPM) to litres per second (L/s), multiply the GPM value by 0.0630902. For example, 10 US GPM equals 0.631 L/s. Imperial GPM is slightly larger: multiply by 0.0757682 to get L/s. Use the Flow Rate tab above for instant results.
What is the difference between PSI and Bar?
PSI (pounds per square inch) is the imperial unit of pressure, while Bar is the metric unit. 1 Bar equals 14.5038 PSI. In HVAC and refrigeration, system pressures are commonly stated in PSI in North America and in Bar or kPa in Europe and Asia.
How many BTU per hour is 1 kW?
1 kilowatt (kW) equals 3,412.14 BTU per hour. This conversion is essential for sizing heat pumps and air conditioning systems, where capacity may be rated in BTU/h (common in the US) or kW (common internationally).
What is a Ton of Refrigeration (TR)?
A Ton of Refrigeration (TR) is a unit of cooling capacity equal to 12,000 BTU/h or 3.51685 kW. It originates from the cooling power of melting one short ton (2,000 lb) of ice in 24 hours. Commercial chillers and large air conditioning systems are commonly rated in TR.
How do DN pipe sizes relate to NPS and actual outside diameter?
DN (Diametre Nominal) is the metric designation and NPS (Nominal Pipe Size) is the imperial equivalent. Neither equals the actual pipe outside diameter (OD). For example, DN25 corresponds to NPS 1 inch, but the actual OD is 33.4 mm. Use the Pipe Sizing tab above for a full reference table covering DN15 through DN300.

Need Engineering Support for Your Heat Pump Project?

Our engineering team can help with system design, pipe sizing, flow calculations, and equipment selection across residential and commercial applications.

Get Expert Advice